INSTALLATION MANUAL
SPLIT-TYPE AIR CONDITIONER
Model MXZ-2A52VA
CFH
dezilitu
A014R
Refer to the installation manual of each indoor unit for indoor unit installation.
FOR INSTALLER
CONTENTS
1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR
SAFETY ......................................................................................... 2
2. INSTALLATION DIAGRAM & ACCESSORIES ..............................2
3. SELECTING THE INSTALLATION LOCATION .............................3
4. OUTDOOR UNIT INSTALLATION .................................................4
5. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND
TEST RUN .....................................................................................5
IMPORTANT NOTES
TO COMPLY WITH THE REQUIREMENTS OF AUSTRALIAN STANDARD
AS 3000 S.A.A WIRING RULES, THE ELECTRICAL WIRING REQUIRED
BETWEEN THE INDOOR AND OUTDOOR UNITS MUST BE INSTALLED
BY A LICENCED ELECTRICAL CONTRACTOR.
SG79Y644H01.indd 1SG79Y644H01.indd 1 29.11.2005 17:04:09 Uhr29.11.2005 17:04:09 Uhr
Vista de pagina 0
1 2 3 4 5 6 7 8 9 10

Indice de contenidos

Pagina 1 - CONTENTS

INSTALLATION MANUALSPLIT-TYPE AIR CONDITIONERModel MXZ-2A52VACFHdezilituA014RRefer to the installation manual of each indoor unit for indoor unit in

Pagina 2 - CAUTION

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANSG79Y644H01SG79Y644H01.indd 9SG79Y644H01.indd 9 29.11.2005 17:04:1

Pagina 3

21. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY● Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the

Pagina 4 - 4. OUTDOOR UNIT INSTALLATION

3APower supply cord (3-core 2.5 mm2)1BIndoor/outdoor unit connecting wire (4-core 1.0 mm2/1.5 mm2)1CExtension pipe According to “Selecting pipe size”1

Pagina 5 - 5-2 FLARING WORK

44. OUTDOOR UNIT INSTALLATION4-1 INSTALLING THE UNIT● Be sure to fi x the unit’s legs with bolts when installing it.● Be sure to install the unit fi r

Pagina 6 - 5-3 PIPE CONNECTION

55. INDOOR/OUTDOOR UNITS CONNECTION FINISHING AND TEST RUN5-1 FLARED CONNECTIONSPIPE LENGTH AND HEIGHT DIFFERENCELimits 2A52VAPipe length per indoor u

Pagina 7

64. Flaring work ● Perform fl aring work using fl aring tool as shown in the right.Outside diameterA (mm)Flare tool for R410A clutch typeConventional

Pagina 8 - 5-10 TEST RUN

7 WARNING:When installing or moving the unit, do not mix anything other than specifi ed refrigerant (R410A) into the refrigerating cycle.If air is mixe

Pagina 9

8 CAUTION:When charging the refrigerant system with additional refrigerant, be sure to use liquid refrigerant. Adding gas refrigerant may change the c