Mitsubishi MOTION CONTROLLERS Q172DCPU Manual de instrucciones Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 448
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
6 - 62
6 POSITIONING CONTROL
Control details for the servo instructions are shown below.
Instruction
Rotation direction
of servomotor
Controllable angle of
arc
Positioning pass
INH
Radius-specified
helical interpolation
less than CW 180°
Clockwise (CW)
Positioning path
End point
Radius R
Central point
<180
Start
point
INH
Radius-specified
helical interpolation
less than CCW 180°
Counter
clockwise (CCW)
0° <
< 180°
Central point
Radius R
Start
point
End point
Positioning path
<180
INH
Radius-specified
helical interpolation
CW 180° or more
Clockwise (CW)
Positioning path
180 360
Central point
End point
Start point
Radius R
<
=
<
=
INH
Radius-specified
helical interpolation
CCW 180° or more
Counter
clockwise (CCW)
180°
360°
Radius R
Start point
End point
Positioning path
Central point
180 360
<
=
<
=
(1) The setting range of end point relative address for the both of circular interpolation
axis and linear interpolation axis is 0 to
(2
31
-1).
The travel direction is set by the sign (+/ -) of the travel value, as follows:
• Positive travel value .............Positioning control to forward direction
(Address increase direction)
• Negative travel value............Positioning control to reverse direction
(Address decrease direction)
(2) The maximum arc radius on the circular interpolation plane is 2
31
-1.
For example, the maximum arc radius for electronic gear 1:1 of unit [mm] is
214748364.7[
µm].
Maximum arc
2
31
-1-2
31
2
31
-1
0
Radius R
Arc central point
Vista de pagina 200