Mitsubishi MOTION CONTROLLERS Q172DCPU Manual de usuario Pagina 178

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 192
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 177
App - 7
A
PPENDICES
APPENDIX 1.4 Forced stop input cable
Generally use the forced stop input cable available as our products. If the required
length is not found in our products, fabricate the cable on the customer side. Make the
forced stop input cable within 30m(98.43ft.).
(1) Q170DEMICBL M
(a) Model explanation
Type : Q170DEMICBL M
1
Cable length [m(ft.)]
5
Symbol
10
1(3.28)
3(9.84)
5(16.40)
3
10(32.81)
15 15(49.21)
20
25
20(65.62)
25(82.02)
30
30(98.43)
05
0.5(1.64)
(b) Connection diagram
(Note) : Use a cable of wire size AWG24.
2
1
EMI.COM
EMI
EMI.COM
EMI
2
1
CPU module side Solderless terminal
5556TL (Terminal)
5557-02R (Connector)
: Twisted pair cable
Vista de pagina 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 191 192

Comentarios a estos manuales

Sin comentarios