Mitsubishi MOTION CONTROLLERS Q172DCPU Manual de instrucciones Pagina 72

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 174
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 71
3 - 3
3 COMMON PARAMETERS
Item Setting range Initial value Remark
Q173DCPU: Up to 2 systems, 32
axes
Q172DCPU: Up to 1 system, 8 axes
None
Set the model name, axis No. and
other details for the servo amplifiers.
External signal input setting
Amplifier input invalid/Amplifier input
valid
Amplifier input invalid
Amplifier setting
Input filter setting
None/0.8ms/1.7ms/2.6ms/3.5ms
3.5ms
High-speed data read setting
One Q172DEX/Q173DPX module
and one input module.
None
Set the high-speed read data.
Refer to Section 4.3.
Individual
parameters
Optional data monitor setting
Set 1 to 3 for each axis.
Q173DCPU: Up to 32 axes
Q172DCPU: Up to 8 axes
None
Set the optional data monitor.
Refer to Section 4.10.
(Note-1) : The forced stop can also be executed by the EMI forced stop terminal of Motion CPU module or forced stop terminal of
servo amplifier besides the forced stop input setting.
Vista de pagina 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 173 174

Comentarios a estos manuales

Sin comentarios