MELSEC-Q
1 GENERAL SPECIFICATIONS AND PRECAUTIONS FOR USE OF I/O
MODULE
1.2.3 I/O combined module
(1)I/O numbers of combined I/O modules
There are two types of combined I/O modules:
• Module using same I/O numbers for input and output
Since same number is used for input and output, the I/O numbers to be used can
be saved.
• Module using sequential I/O numbers for input and output
Since I/O assignments are the same for A series, it is useful when replacing
modules from those of A series.
Vacant
32 points
Input (X) Output (Y)
X00
X1F
Y00
Y1F
00
1F
X00
X1F
00
1F
Vacant
Y20
Y3F
20
3F
Input (X) Output (Y)
32 points
32 points
Module using same I/O numbers for input
and output (QH42P)
Module using sequential I/O numbers for input
and output (QX41Y41P)
(2)When using the QH42P, QX41Y41P or QX48Y57, configure it with the following
devices.
Part name Detail
CPU PLC Product of product information [011120000000000-A] or later
GX Developer
SW5D5C-GPPW or later
The CPU PLCs other than those listed above cannot be used.
When the SW4D5C-GPPW is used, the response time cannot be set
(fixed at 10ms).
Set OUTPUT for the I/O allocation.
For how to check product information of the CPU module, refer to QCPU User's
Manual (Hardware Design, Maintenance and Inspection).