4 Allen-Bradley PLCs
2-149
Chap.2
4.5.4 Logix DF1 (Full Duplex)
Word Device
Device Symbol
Device Name
HG PLC
Address Range
Read
/Write
Address
Gradual
INT INT INT 0 - 999999 R/W 10 (*1)
REAL REAL REAL 0 - 9999991 R/W 10 (*2)
DINT DINT DINT 0 - 9999991 R/W 10 (*2)
SINT SINT SINT 0 - 999999 R/W 10 (*1)
(*1) Address selection rule is as follows.
Standard device address format of WindO/I-NV2
INT
255255
Example
ControlLogix Address --- INT 123:255
WindO/I-NV2 Address --- INT 23255
3 di
g
its Element number
3 di
g
its File number
Allen-Bradley device address format
INT
255
:
255
3 di
g
its Element number
3 di
g
its File number