Mitsubishi RS232/485/LAN Serial Communication Control Manual Pagina 312

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 349
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 311
Chapter2 Connection to a PLC
2-312
18.4 Environment Settings
The following shows the settings of the communication port for performing communications
between the Mitsubishi inverter FREQROL series and MICRO/I.
18.4.1 Environment settings for connecting the device to a Mitsubishi inverter
Items Details
Serial Interface RS-485 (4wire)
Inverter No. 01 - 31
Baud Rate (bps)
4800/9600/19200
Data Bits (bit) 7,8
Stop Bits (bit)
1 / 2
Parity
Use the same
settings as for the
MICRO/I.
Odd / Even / None
Ignore Write Error Enable/Disable (*)
Terminator CR only
Communication check time interval Set to a value other than “0”.
(*)When you check “Ignore Write Error.” MICRO/I don’t display “Host communication Error”
even if the Inverter returns NAK Error response.
MICRO/I set the error code from the inverter to LSD 112
Vista de pagina 311
1 2 ... 307 308 309 310 311 312 313 314 315 316 317 ... 348 349

Comentarios a estos manuales

Sin comentarios